Abstract:
The purpose of this paper is to examine water use estimation in hydel and thermal electric power plants
in selected regions i.e. Coastal, Rayalaseema and Telangana regions of Andhra Pradesh. The study
primarily focuses on the realistic fundamental premise that thermal electric and hydro electric energy
generation is responsible for the largest monthly volume of water withdrawals in four seasons (i.e.
summer, rainy, winter and post monsoon season) of a year. These enormous water withdrawals by these
hydel and thermal power plants can have significant influence on local surface water resources.
However there are very few studies of determinants of water use in hydel and thermal electric
generation. Analysis of hydel and thermal electric water use data in the existing power plants clearly
indicates that there is wide variability in unitary hydel and thermal electric water use within the system.
The multivariate regression procedures were used to identify the significant determinants of thermal
and hydel water withdrawals in various power plants i.e. five hydel and four thermal power plants. The
estimated regression coefficients indicate that the best explanatory variables for the total quantity of
hydel water withdrawals are storage capacity, tail water level and actual generation and thermal water
withdrawals are condenser cooling and ash disposal. The unit variability of unit water usage indicates
that there is significant potential for water conservation in existing power plants. Apart from this as
water is no longer available as a free good; it calculates the real value of water in selected power plants
using Water Valuation Techniques such as Residual Value and Opportunity costs.